| Feature |
Dell™ PowerVault™ MD3200 Series |
| Hard Disk Drives |
MD3200 - Up to twelve (12) 3.5 inch SAS, Near-line SAS and SSD drives MD3220 - Up to twenty-four (24) 2.5 inch SAS, Near-line SAS and SSD drives |
| 3.5" Drive Performance and Capacities |
15,000 RPM SAS drives available in 300 GB, 450 GB and 600 GB |
| 7,200 RPM Near-line SAS drives available in 500 GB, 1TB and 2TB |
| 2.5" Drive Performance and Capacities |
15,000 RPM SAS drives available in 73 GB and 146 GB |
| 10,000 RPM SAS drives available in 146 GB and 300 GB |
| 7,200 RPM Near-line SAS drives available in 500 GB |
| Solid State Drive (SSD) available in 149 GB (available in 3.5" HDD carriers) |
| Expansion Capabilities |
Expand up to a base of 120 hard drives with an optional Premium Feature Key to scale up to 192 total drives using MD1200 and/or MD1220 expansion enclosures |
| Host Connectivity |
| Single Controller Models |
Supports up to 4 servers directly connected |
| Dual Controller Models |
Supports up to 8 servers directly connected in a non-HA configuration or 4 servers in a HA configuration |
| Storage Controllers and RAID Levels |
| Storage Controllers |
Each controller contains 2GB of battery-backed cache |
| Dual controllers operate in an active-active environment mirroring each other's cache |
| Cache protection is provided via flash memory for permanent data protection |
| RAID Levels |
Support for RAID levers 0, 1, 10, 5, 6 |
| Up to 120 physical disks per group in RAID 0, 1, 10 |
| Up to 30 physical disks per group in RAID 5, 6 |
| Up to 512 virtual disks |
| Array Management and Optional Premium Features |
| Array Management |
2nd generation Modular Disk Storage Manager |
| Multi-path software provides failover management of redundant data paths between the server and storage array |
| Optional Premium Features |
Snapshots: Up to 16 snapshots per virtual disk and 256 per system |
| Snapshots Plus Virtual Disk Copy: Up to 16 simultaneous virtual disk copies |
High Performance Tier firmware upgrade increases array IO performance Additional Hard Drives - capacity up to 192 hard drives
|
| Back-Panel Connectors (per controller) |
| Host Connectivity |
Four x4 6Gb SAS (SFF8088 mini connector) |
| Expansion Connectivity |
One x4 6Gb SAS (SFF8088 mini connector) |
| Remote Management |
One RJ-45 1Bb Ethernet |
| Service Management |
One PS/2 Serial |
| LED Indicators |
| Front Panel |
1 two-color LED indicator for system status, 1 single-color LED indicator for power, 1 LED unused in this system |
| Hard Drive Carrier |
1 single-color activity LED, 1 two-color LED status indicator per drive |
| Storage Controller |
1 one-color LED power indicator, 1 one-color LED controller fault indicator, 1 one-color LED controller identifier, 1 one-color LED cache activity indicator, 1 one-color LED battery fault indicator |
| Power Supply/Cooling Fan Module |
3 one-color LED status for AC status, DC status and power supply cooling fan fault |
| Power Supplies (per supply) |
| Wattage |
600 W peak output |
| Maximum Heat Dissipation |
150 W |
| Input Voltage Range |
90 to 264 VAC |
| Frequency Range |
47 to 63 Hz |
| Maximum Input Current at Rated Power |
55 A for 10ms or less, 25 A for 10-150ms |
| Available Hard Drive Power (per slot) |
| Supported Continuous Consumption |
3.5" drive: 25 Watts |
| 2.5" drive: 12 Watts |
| Physical |
| Height x Width x Depth |
MD3200: 8.68cm (3.42") x 44.63cm (17.57") x 56.1cm (22.09") |
| MD3220: 8.68cm (3.42") x 44.63cm (17.57") x 50.8 (20") |
| Weight |
MD3200: 29.3kg (64.59 lbs.) (maximum configuration) |
| MD3220: 24.2kg (53.35 lbs.) (maximum configuration) |
| Environmental |
Expanded Temperature Operating Range |
Continuous Operation: 10C to 35C, 10% to 80% relative humidity (RH) with a 26C max dew point. De-rate maximum allowable dry bulb temperature at 1°C/300 meters above 900 meters (1 degree F per 550 feet) 10% of annual operating hours: 5C to 40C, 5% to 85%RH with a 26C max dew point. For temperatures between 35 and 40C, de-rate maximum allowable dry bulb temperature 1°C/175 meters above 950 meters (1 degree F per 319 feet) |
| Relative Humidity |
1% of annual operating hours: -5C to 45C, 5% to 90%RH, with a 26C max dew point. For temperatures between 40 and 45C, de-rate maximum allowable dry bulb temperature 1°C/125 meters above 950 meters (1 degree F per 228 feet) |
| Altitude |
Operating: -16 to 3048 m (-50 to 10,000 ft) |
| Note: For altitudes above 2950 feet, the maximum operating temperature is de-rated 1°F/550 ft. |