Dell PowerEdge 2850 Rackmount Server - Used Pull
- Dual 3.0GHz XEON CPUs - 1MB Cache - 800Mhz FSB
- 2GB PC3200 ECC RAM
- 6 bay SCSI Hot Swap Backplane
- PERC 4e/DI SCSI RAID Controller with 256MB Cache
- CD ROM Drive
- Dual 700W AC Power Supplies
- NO HARD DRIVES or TRAYS included, please add to order as separate line item. Add up to 6 x 80pin hot-swappable SCSI hard drives to this system.
|
| |
 |
 |
Dell PowerEdge 2850 Rackmount Server - Used Pull
- Dual 3.0GHz XEON CPUs - 1MB Cache - 800Mhz FSB
- 2GB PC3200 ECC RAM
- 6 bay SCSI Hot Swap Backplane
- PERC 4e/DI SCSI RAID Controller with 256MB Cache
- CD ROM Drive
- Dual 700W AC Power Supplies
- NO HARD DRIVES or TRAYS included, please add to order as separate line item. Add up to 6 x 80pin hot-swappable SCSI hard drives to this system.
Compatibility
|
| |
 |
 |
| Processor |
| Processor type |
Dual 3.0GHz Intel® Xeon™ processors |
| Front-side bus speed |
800 MHz |
| L2 cache |
1MB internal cache |
| Expansion Bus |
| Bus type |
PCI-X, PCI Express |
| Expansion slots via riser card cage: |
|
| PCI-X |
one 3.3-V, 64-bit, 100-MHz or three 3.3-V, 64 bit, 133MHz |
| PCI Express |
one x4 lane width one x8 lane width |
| Memory |
| Architecture |
144-bit ECC registered PC2-3200 DDR2 SDRAM DIMMs, with two-way interleaving, rated for 400-MHz operation |
| Memory module sockets |
Six 240-pin |
| RAM |
2 GB |
| Drives |
| SCSI hard drives |
up to six 1-inch, internal, hot-plug, Ultra320 SCSI |
| Optical drive |
Internal CD-ROM drive |
| Connectors |
| Externally accessible |
| Back |
| NIC |
Two RJ-45 (for integrated 1-Gigabit NICs) |
| PS/2-style keyboard |
6-pin mini-DIN |
| PS/2-compatible mouse |
6-pin mini-DIN |
| Serial |
9-pin, DTE, 16550-compatible |
| USB |
Two 4-pin, USB 2.0 compliant |
| Video |
15-pin VGA |
| Front |
| Video |
15-pin VGA |
| USB |
Two 4-pin, USB 2.0 compliant |
| Internally accessible |
| SCSI channels |
Two 68-pin U320 SCSI |
| Video |
| Video type |
ATI Radeon 7000-M video controller; VGA connectors |
| Video memory |
16 MB |
| Power |
| AC power supply (per power supply) |
| Wattage |
700W |
| Voltage |
84 -264 VAC, autoranging, 47-63 Hz, 10.1 A |
| Heat dissipation |
2388 BTU/hr maximum |
| Maximum inrush current |
Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 25 A per power supply for 10 ms or less. |
| Batteries |
|
| System battery |
CR 2032 3.0-V lithium ion coin cell |
| ROMB battery (optional) |
4.1-V lithium ion |
| Physical |
| Height |
8.656 cm (3.40 in) |
| Width |
44.7 cm (17.6 in) |
| Depth |
75.68 cm (29.79in) |
| Weight (maximum configuration) |
26.76 kg (59 lb) |
| Environmental |
| Temperature |
| Operating |
10° to 35°C (50° to 95°F) |
| Storage |
–40° to 65°C (–40° to 149°F) |
| Relative humidity |
| Operating |
8% to 85% (noncondensing) with a maximum humidity gradation of 10% per hour |
| Storage |
5% to 95% (noncondensing) |
| Maximum vibration |
| Operating |
0.25 G at 3–200 Hz for 15 min |
| Storage |
0.5 G at 3–200 Hz for 15 min |
| Maximum shock |
| Operating |
One shock pulse in the positive z axis (one pulse on each side of the system) of 41 G for up to 2 ms |
| Storage |
Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms |
| Altitude |
| Operating |
–16 to 3048 m (–50 to 10,000 ft) |
| Storage |
–16 to 10,600 m (–50 to 35,000 ft) |
Click here to view the manufacturers item description/brochure |
| |
 |
 |
Don't forget to add hard drives to your server. Plus, all these upgrades will work with this Dell PowerEdge server: |
| |
| |
| |
|
|
|
|
| |
|
|
|
|